A confined space in construction falls under OSHA’s construction confined space rule, not the general industry permit-space rule, which excludes construction work. The basics carry over: identify the space, test the air, write a permit, post an attendant and plan the rescue. The construction rule adds a competent person who finds every space before work starts, coordination between every contractor on site, continuous air monitoring, early warning for water or material that can’t be shut off, and the option to suspend a permit instead of cancelling it.

What counts as a confined space on a construction site?
A space is a confined space when it passes three tests. You can get your whole body inside it. The way in or out is limited. And it wasn’t built for someone to stay in.
It becomes a permit-required confined space when it has, or could have:
- air that could be short on oxygen, flammable or toxic;
- water, soil or loose material that could bury or drown someone (engulfment);
- a shape that could trap someone, like walls that narrow toward the bottom;
- any other serious hazard.
OSHA’s own list of where these show up on a jobsite reads like a utility plan: sewer, storm drain, electrical and communication manholes, lift stations and water mains, tanks, boilers and digesters, elevator and pump pits, transformer vaults, HVAC ducts, concrete pier columns and drilled shafts.
In residential work, OSHA’s guidance says attics and crawl spaces usually won’t trigger the permit requirements, because most are easy to get out of. A crawl space with one tight hatch and a spray-foam crew inside is a different call, and that’s exactly the call the rule hands to a competent person. Trenches and other excavations, underground construction and diving fall under their own rules instead.
Subpart AA vs the general industry rule: five things that change
If your crews learned confined space entry in a plant, most of it still applies.
| What the construction rule adds | What it means on your site |
|---|---|
| A competent person identifies the spaces | Before work starts, someone who can spot hazards and has authority to fix them lists every space and which need a permit. |
| The controlling contractor coordinates | What’s known about each permit space reaches every crew that enters or works nearby. |
| Continuous monitoring | The air is watched the whole entry, not just checked at the start, wherever equipment exists. |
| Early warning for engulfment | If water or material can’t be shut off upstream, something has to warn the crew in time to get out. |
| Permits can be suspended | A temporary problem can pause a permit instead of killing it, with a full reassessment before reentry. |
The competent person’s job doesn’t end at the first walk-through. When a space changes use or shape, as spaces do on a build, it gets evaluated again.
Coordination matters because a jobsite rarely has just two parties. The host employer, the one that owns or manages the property, briefs the controlling contractor, who briefs every crew that enters and any trade whose work could create a hazard in the space. Crews coordinate when two of them enter at once and get debriefed afterward.
Early warning is easiest to picture in a storm line. Your crew is working inside, and rain is falling upstream. The rule’s examples are an alarm wired to sensors upstream, or a lookout with the equipment to reach the crew right away.
On testing, the order stays the same as in a plant: oxygen first, then flammable gas, then toxic gases.
Who has to be at the opening?
Every permit entry has four roles.
- Entrants do the work, stay in contact with the attendant, and get out on an order, an alarm or a warning sign.
- The attendant stays outside for the whole entry, keeps count of who’s in, orders everyone out, calls rescue and does nothing else. See the full confined space attendant duties.
- The entry supervisor checks and signs the permit, confirms rescue is ready, and suspends or cancels the permit when conditions call for it.
- The rescue service has to reach a victim in time for the hazards in that space and practice a rescue at least once every 12 months.
One attendant can watch more than one space only if every duty can still be done for each, and the plan says how they handle an emergency in one without leaving the others.
What you need on site
A quick check before the first entry on a new site:
- A competent person’s list of every confined space, marked permit or non-permit
- A written permit for each permit space, signed by the entry supervisor
- A gas monitor reading continuously where the crew is working
- Forced-air ventilation and duct to push fresh air to where the crew is working
- A dedicated attendant outside the opening for the whole entry
- A tripod or davit with a retrieval winch for any vertical entry deeper than five feet
- A rescue service that can get there in time and has practiced in the last year
- Radios that keep the attendant and entrants on one channel, and lighting safe for the space
- An early-warning setup if water or material can reach the space from upstream
Where Tiger’s people and equipment fit
The rule says what has to be at the opening, and Tiger Safety Rentals supplies the trained people and gear to put it there. On a busy site, the attendant is usually the first person to get borrowed for something else. Trained confined space attendants hold the post and nothing else. In the field the role is often called a hole watch.
Personal and area gas monitors read oxygen, carbon monoxide, flammable gas and H2S, and wireless alarm networks carry an alarm from inside the space to the attendant and the perimeter.
For fresh air, explosion-proof electric and pneumatic blowers push air through duct down to where the crew is working.
Confined space rescue equipment includes man-rated winches on tripods or davits, rescue lifelines, stretchers and SCBA. Standby rescue comes as a full team, or as equipment plus an attendant. Tiger’s standby rescue team can also be the designated rescue service for your entry, including the practice rescue the rule requires every 12 months.
A permit-to-work coordinator gives the controlling contractor one point of control for permits. Intrinsically safe radios keep the attendant, the entrants and any upstream lookout on one channel, and explosion-proof lighting keeps the space lit where flammable gas could collect. Tiger’s safety professionals can also act as the competent person who identifies and classifies the confined spaces on site before work starts.

Frequently asked questions
Does 1910.146 apply to construction?
No. 1910.146(a) states that it does not apply to construction. Construction work falls under 29 CFR 1926 Subpart AA, which OSHA published in May 2015.
Who is the competent person for confined spaces in construction?
Someone who can identify existing and predictable hazards and has the authority to correct them right away. Under 1926.1203(a), that person identifies every confined space and permit space before work begins.
What does 1926.1204 require?
A written permit space program. It covers keeping unauthorized people out, evaluating hazards, testing, ventilation, communication, lighting and rescue equipment, continuous monitoring, at least one attendant, rescue procedures and coordination between employers.
Is a trench a confined space under Subpart AA?
No. Excavations, including trenches, are excluded from Subpart AA and fall under Subpart P instead.
Are attics and crawl spaces confined spaces in construction?
They can be confined spaces, but OSHA’s residential guidance says they usually won’t trigger the permit requirements. A competent person still has to evaluate each one, and a tight exit or hazardous work inside can change the answer.
Sources
- 29 CFR 1926 Subpart AA (1926.1200 to 1926.1213): OSHA’s confined space rule for construction.
- 29 CFR 1926.1201: who the rule covers, what it excludes, and OSHA’s list of common jobsite confined spaces.
- 29 CFR 1926.1202: definitions of confined space and permit-required confined space.
- 29 CFR 1926.1203: the competent person, reevaluation, alternate procedures and coordination between employers.
- 29 CFR 1926.1204: the permit space program, including continuous monitoring, early warning, attendants and lighting.
- 29 CFR 1926.1205: entry permits, including suspending a permit.
- 29 CFR 1926.1208 to 1926.1210: duties of entrants, attendants and entry supervisors.
- 29 CFR 1926.1211: rescue services, retrieval equipment and the annual practice rescue.
- 29 CFR 1910.146: the general industry permit-space rule, which excludes construction.
- 29 CFR 1926 Subpart P: excavations, including trenches.
- OSHA 3914, Confined Spaces in Residential Construction: guidance on attics and crawl spaces.
Staff and equip your next construction entry
Tiger Safety Rentals supplies confined space attendants, gas detection, ventilation and rescue equipment as one order, scheduled around the entry. See safety equipment and personnel for construction, or call 888-365-5220 for 24/7 dispatch.